CLIA Waived | FDA Cleared
12 Panel Cup with PCP
SKU SM-CDOA-6125
AMP | OPI | MET | BZO | COC | MTD | OXY | BUP | MDMA | THC | BAR | PCP
$6.50 $6.00 volume pricing on product
Mayflower Bioscience
Professional multi-panel urine screening cups for workplace, clinical, and forensic programs. Clear results in five minutes — built for high-volume buyers.
Four cup configurations covering 12, 14, and 16 panels - including CLIA-waived workplace screening and forensic-use cups with ETG and specialty panels.
CLIA Waived | FDA Cleared
SKU SM-CDOA-6125
AMP | OPI | MET | BZO | COC | MTD | OXY | BUP | MDMA | THC | BAR | PCP
$6.50 $6.00 volume pricing on product
Forensic Use Only
SKU SM-CDOA-9125FUO | 120 ml
AMP | BUP | BZO | COC | MET | MTD | OPI | OXY | PCP | THC | ETG | FEN
$6.50 $6.00 from $3.70 in volume
Forensic Use Only
SKU SM-CDOA-7145FUO
12-panel core | BAR | FEN | ETG | PCP
$6.50 $6.00 from $3.78 in volume
Forensic Use Only
SKU SM-CDOA-8165FUO
14-panel coverage | TCA | KRA
$5.50 $5.00 from $2.59 in volume
Need the full catalog view? See Our Products or the shop.

Each Mayflower cup combines collection, temperature check, and immunoassay screening in one device - so programs can collect, read, and document without extra analyzers.
Rapid immunoassay cups are one-step lateral-flow tests. Collect, wait, then read the control (C) and test (T) lines. Always follow the insert packed with the lot you receive.
Open a sealed pouch and use the cup promptly. Have the donor fill to the marked line, then cap immediately. Keep the cup upright.
At 2 4 minutes, check the temperature strip. A reading in the valid range supports that the specimen was provided at collection not substituted from a stored sample.
Peel the privacy label if present. Interpret at 5 minutes. A missing control line means the test is invalid discard and repeat with a new cup.
Cutoffs below are the labeled screening thresholds in ng/mL. These cups provide a preliminary qualitative result. Confirm presumptive positives with GC-MS or LC-MS/MS before employment, clinical, or legal action.
| Cup | Status | Variant / added panels | Key cutoffs | Best for | From |
|---|---|---|---|---|---|
| 12 Panel with PCP | CLIA Waived | FDA Cleared | PCP + BAR on a 12-panel core | PCP/25 | THC/50 | OXY/100 | BUP/10 | Workplace, staffing, probation | $6.00 list |
| 12 Panel ETG + FEN | Forensic Use Only | ETG alcohol metabolite + FEN | ETG/300 | FEN/20 | PCP/25 | Treatment, MAT, alcohol monitoring | $3.70 volume |
| 14 Panel PCP + ETG + FEN | Forensic Use Only | BAR, PCP, ETG, and FEN together | BAR/300 | PCP/25 | ETG/300 | FEN/20 | Courts, corrections, expanded forensic screens | $3.78 volume |
| 16 Panel KRA + TCA | Forensic Use Only | Kratom and tricyclic antidepressants added | KRA/500 | TCA/1000 | ETG/300 | FEN/20 | Clinical forensic programs, emerging-drug coverage | $2.59 volume |
| Panel | Substance | Cutoff | What it is looking for |
|---|---|---|---|
| AMP | Amphetamines | 1000 ng/mL | Prescription and illicit amphetamines |
| MET | Methamphetamine | 1000 ng/mL | Methamphetamine; not a substitute for AMP |
| COC | Cocaine | 300 ng/mL | Cocaine metabolite |
| OPI / MOP | Opiates / morphine | 300 ng/mL | Heroin, codeine, morphine not FEN |
| OXY | Oxycodone | 100 ng/mL | Oxycodone / oxymorphone class |
| BUP | Buprenorphine | 10 ng/mL | Suboxone / Subutex compliance and diversion |
| MTD | Methadone | 300 ng/mL | Methadone maintenance |
| BZO | Benzodiazepines | 300 ng/mL | Xanax, Valium, Klonopin class |
| BAR | Barbiturates | 300 ng/mL | Phenobarbital, butalbital, related barbiturates |
| MDMA | Ecstasy | 500 ng/mL | MDMA |
| THC | Marijuana | 50 ng/mL | Cannabis metabolite |
| PCP | Phencyclidine | 25 ng/mL | PCP |
| ETG | Ethyl glucuronide | 300 ng/mL | Alcohol metabolite; longer window than breath alcohol |
| FEN | FEN | 20 ng/mL | Synthetic opiate not detected by OPI strips |
| TCA | Tricyclic antidepressants | 1000 ng/mL | Amitriptyline class 16 panel |
| KRA | Kratom | 500 ng/mL | Mitragynine class 16 panel |
Result guide
Lines form as urine wicks up each strip. Color intensity can vary; any distinct line in the test region is typically negative. Read in good light at five minutes.

Control line (C) present. No line in the test region (T) for that drug. Treat as a preliminary positive and confirm in a laboratory.
Lines in both C and T. A faint T line still counts as negative for that panel.
No control line. Do not report a result. Repeat with a new cup from an unopened pouch. If it persists, contact Mayflower.
For federally regulated workplace testing, see SAMHSA workplace programs. Rapid cups used here are screening devices, not SAMHSA laboratory certifications.
U.S. screening programs
Multi-panel cups remain the default on-site format for U.S. occupational health, treatment, and supervision programs because they answer a practical question in one collection: which major drug classes are present right now?
It covers the opiate classes programs actually miss on cheap 5-panel screens - oxycodone, methadone, buprenorphine - plus stimulants, benzodiazepines, barbiturates, MDMA, THC, and PCP. Mayflower's CLIA-waived 12 panel with PCP is built for documented professional screening.
Standard opiate antibodies do not detect FEN. CDC overdose data continue to show illicit FEN in a large share of U.S. overdose deaths. That is why forensic cups in this collection add a dedicated FEN strip at 20 ng/mL.
Breath or blood alcohol collapses within hours; ethyl glucuronide in urine can remain detectable for a day or more after drinking. Treatment and sober-living programs specify ETG rather than relying on a clinic-door breathalyzer alone.
Mayflower Bioscience is a St. Louis distributor - not a commodity marketplace. If you need lot documentation, volume quotes, or help matching a panel list to a written policy, start with About or Contact Us.
Match the cup to the population and the paperwork you must keep not to a generic 12 panel | label.
Pre-employment, random, post-accident, and reasonable-suspicion screens. Start with the CLIA-waived 12 panel PCP cup so oxycodone and buprenorphine are not invisible.
Need alcohol between visits and street FEN on the same void. Use the 12 panel ETG + FEN cup (forensic use).
Broader sedative and dissociative coverage plus FEN. The 14 panel PCP/ETG/FEN cup is the expanded forensic option.
When policy also tracks tricyclics or kratom, step up to the 16 panel. Confirm any clinical decision with laboratory toxicology.
Work backwards from the substances your policy names, then from whether you need a CLIA-waived device or a forensic-use screen.
Choose the 12 panel with PCP. It is the only cup in this collection labeled CLIA waived and FDA cleared. Do not substitute a forensic ETG/FEN cup when your procedure requires a waived device.
You need ETG. Breath alcohol on collection day will miss drinking earlier in the week. Use a forensic cup that includes ETG/300.
You need a FEN strip. An OPI-negative result does not rule out FEN. See CDC overdose prevention for why programs added this panel.
Only the 16 panel adds KRA/500 and TCA/1000. Use it when those drugs are written into your panel list not as a default for every workplace.
FDA explains CLIA waiver for in vitro diagnostics here: CLIA Waiver by Application.
Browse MayFlower Bioscience collections by panel count, analyte, and compliance type — every configuration is available at wholesale volume pricing.
12 Panel Drug Test CupsThe classic workplace & clinic configuration
14 Panel Drug Test CupsExpanded coverage with PCP, ETG & FEN
16 Panel Drug Test CupsMaximum coverage incl. kratom & TCA
FEN Drug Test CupsDedicated FEN panels at a 20 ng/mL cutoff
ETG Alcohol Drug Test CupsAlcohol detection up to 80 hours
PCP Drug Test CupsPhencyclidine panels for workplace & justice
Kratom Drug Test CupsEmerging-substance (KRA) coverage
CLIA-Waived Drug Test CupsFDA-cleared cups for clinical programs
Forensic-Use Drug Test CupsFUO panels for courts & corrections
Wholesale Drug Test CupsVolume pricing & bulk fulfillment
Short answers for purchasing and on-site use. Your package insert is the lot-specific authority.
Preliminary lines form in about five minutes. Read then; do not interpret after eight minutes. Temperature is checked at 2 4 minutes.
The 12 panel PCP cup is CLIA waived and FDA cleared for professional diagnostic screening. Cups that add ETG, FEN, or kratom in this collection are labeled Forensic Use Only they are not for waived clinical diagnostic use. See the FDA CLIA waiver page.
Yes. Panels such as BZO, BUP, MTD, OXY, BAR, and TCA are aimed at prescription classes as well as illicit use. A line result is not a dosage or prescription-validity determination.
FEN is a synthetic opiate. Morphine-class OPI strips do not reliably detect it. A dedicated FEN/20 panel is required for that exposure.
It helps show the urine was produced at collection. Out-of-range temperature is a reason to stop and follow your substitution / recollection procedure.
Yes. Immunoassay cups are screening tests. Confirm presumptive positives by GC-MS or LC-MS/MS before employment, clinical, or legal decisions.
Yes. Quantity breaks appear on each product page (examples: 12 panel ETG/FEN from $3.70, 16 panel from $2.59, 14 panel from $3.78). Request a quote for standing orders. Free shipping on 100+ cups.
Same-day shipping is offered on qualifying orders (see product pages). The 12 panel ETG/FEN cup may show backorder confirm stock before you schedule a collection event.
Keep pouches dry at the temperature range on the box, away from direct sun. Do not use damaged or expired pouches.
Visit the Research Insights blog, product index, or shop.
Mayflower Bioscience
St. Louis distribution for professional urine cups, volume pricing, and a team that will match panels to your written policy.
314-485-5210
sales@mayflowerbio.com
Mayflower Bio science, LLCnHelix Centern1100 Corporate Square DrivenSt. Louis, MO 63132nUnited States (USA)
Offers are valid for a limited time only and reflect multi-annual discounts. See our Terms of Service, Shipping, and Returns policies.
We use cookies to improve your experience on our site. By using our site, you consent to cookies.
Manage your cookie preferences below:
Essential cookies enable basic functions and are necessary for the proper function of the website.
These cookies are needed for adding comments on this website.
Statistics cookies collect information anonymously. This information helps us understand how visitors use our website.
Google Analytics is a powerful tool that tracks and analyzes website traffic for informed marketing decisions.
Service URL: policies.google.com (opens in a new window)
SourceBuster is used by WooCommerce for order attribution based on user source.